Digi-Sense Data Logging Light Meter with NIST-Traceable Calibration

Representative image only.
Digi-Sense Item # EW-20250-00
Ensure lighting standards and increase system efficiencies with precision measurement accuracy
  • Reliable measurements, guaranteed! Precalibrated to NIST-traceable standards
  • Expanded range of 0 to 400 klux (0 to 40 kftc) meets a wide range of application requirements
  • Silicon photo diode with spectral response filter ensures precision accuracy of ±3%
  • Record up to 87,000 measurements for expanded data analysis capability
  • Data logging software with graphical display provides quick and easy data interpretation

$163.20USD / Each
$192.00USD / Each
Time to recalibrate?
for an additional
$179.80USD / Each

SPECS & DESCRIPTION

Specifications & Description

  • Min Measurement (Fc)0
  • Max Measurement (Fc)40000
  • Min Measurement (Lux)0
  • Max Measurement (Lux)400000
  • Resolution0.01 Fc, 0.01 Lux
  • Accuracy±3% of reading ± 0.5% full-scale; ±4% of reading ± 10 digits above 10,000 Lux
  • FunctionDatalogging, min/max/hold, record/recall, auto power-off, low-battery indicator, user-selectable Lux or Fc
  • Display Type4000-count LCD (backlit)
  • Data Logging87,000 readings
  • InterfaceUSB
  • Width (cm)5
  • Height (cm)16
  • Depth (cm)2.7
  • PowerAAA Battery (3)
  • DescriptionData Logging Light Meter with NIST Traceable Calibration
Two year warrantyNIST Traceable Calibration

Includes

USB cable, software CD, canvas carrying case, three AAA batteries, and NIST-traceable calibration report with data supplied by InnoCal.

Key Features

  • Reliable measurements, guaranteed! Precalibrated to NIST-traceable standards
  • Expanded range of 0 to 400 klux (0 to 40 kftc) meets a wide range of application requirements
  • Silicon photo diode with spectral response filter ensures precision accuracy of ±3%
  • Record up to 87,000 measurements for expanded data analysis capability
  • Data logging software with graphical display provides quick and easy data interpretation

More About this Item

The Digi-Sense data logging light meter is designed for precision light intensity measurements, in lux or footcandles, for indoor/outdoor environments. Meter will help you meet lighting codes and standards, ensuring safety and quality control requirements while increasing comfort levels and productivity. Plus the NIST-traceable precalibration means you get reliable measurements, saving you time and money!

Intuitive interface makes this light meter easy to set up and use right out of the box. Meter features user-selectable lux or ftc units, max/min, and hold functions, allowing you to easily control measurement readings. The included software allows you to view measurement data in graphical formats as well as record and download data, via USB connectivity, to your PC for further analysis.

ACCESSORIES

REVIEWS

Q&A

Do you have questions about this product?

Get answers from real customers and in-house experts with AnswerBox.

4 Questions | 4 Answers
Displaying questions 1-4
  • Q:

    How much is the annual calibration check for this equipment?
    Asked on 12/22/2016 by Ida from Canada

    1 answer

    • STAFF EXPERT

      A:

      The annual calibration is item #17000-27.

      Answered on 12/28/2016 by Nicole from Technical Support
  • Q:

    We would like to purchase light meter with NIST Traceable Calibration. I found that it is recommended to send back to InnoCal for annual checking. However when I check the scope of InnoCal, it seems the accredited scope from InnoCal do not include any measurement for lux meter.
    Would you confirm that InnoCal can provide measurement service for lux meter.
    Asked on 8/6/2015 by Timothy Ng from Hong Kong

    1 answer

    • STAFF EXPERT

      A:

      The certification supplied with the unit is not accredited, it is traceable to NIST. For an accredited certificate, the meter must be ordered with the 17101-44 certificate and 17100-03 accreditation.

      Answered on 8/7/2015 by Dan from Technical Support
  • Q:

    Will this meter measure light from LED fixtures?
    Asked on 9/4/2014 by William

    1 answer

    • STAFF EXPERT

      A:

      This meter will measure any visible light source.

      Answered on 9/5/2014 by Dan from Technical Support
  • Q:

    What is the diameter of the light aperture? Measurements made for the ANSI FL1 Flashlight Performance Standard require a 100mm^2 surface area of the aperture. Does this instrument meet that requirement?
    Asked on 7/30/2014 by NH

    1 answer

    • STAFF EXPERT

      A:

      The aperture diameter is not applicable for our 20250-00 light meter due to it being an incident light meter and that the photocell collects light from all different angles.
      If you are referring to the external sensor lens (the white capped sensor) then that would be 1” in diameter. Light is collected in this sensor at angle ranges from 0 to 180 degrees.

      Answered on 8/7/2014 by Jay from Technical Support
Displaying questions 1-4

Do you have a question about this product? 

CUSTOMER SUPPORT

Need Help with this product?

Our specialists are here to help you find the best product or part available for your application. Call or Email us and we will make sure you get the right product or part for the job.

Call Us At1-800-323-4340
Live chat