Supplier Certificate of Analysis (CoA) is included with product shipment.
Key Features
Accredited by A2LA to ISO/IEC 17025/2017 and ISO 17034:2016
Certified to DQS to ISO 9001:2015
Multi-element interferents check solution A3 in 5% HNO3/tr. HF matrix
125 mL bottle
More About this Item
Our Contract Laboratory Program (CLP) standards allow you to Calibrate with Confidence®. The standards are to be used in conjunction with the Statement of Work for Inorganic Analysis; Multi-Media/Multi-Concentration Document Number ILM 05.3/ISM 01.2.
The final ICP check, performed in our own laboratories, is your stamp of assurance. We calibrate our instruments with traceable reference materials and show you the actual found value of the solution you receive, not just an ideal, calculated number as so many other standards manufacturers do. The combination of elements, concentrations and matrices listed have been diagnosed by SPEX CertiPrep for convenience of use and stability.
US EPA SOW ILM 05.3/ISM 01.2 gives specific procedures for the methods of analysis, target elements, and concentrationlevels. Standards are specified not only by the elements present and their relative concentrations, but also the order and frequency of running standards, blanks and samples. Details of these specifications may be found in the US EPA SOW ILM 05.3/ISM 01.2 in the following sections:
• Exhibit C, Inorganic Target Analyte List (TAL) • Exhibit D, Analytical Methods • Exhibit E, QA/QC Requirements
We also provide a solution of alternate interferents and alternate analysis. Alternate interferents A (INT-A2) and alternate analytes B (INT-B2) may be prepared in combination with the INT-A1 and INT-B3 solutions mentioned, or any combination involving the four solutions, depending on the analytes and interferents of interest to you. We provides ICP-MS interferents and interferent check solutions for SW-845.
Can’t find the standards you are looking for? Spex CertiPrep®can make custom standards to meet your exact needs. Contact us for more information at [email protected] or call us at 732-549-7144.
Chemicals sold by Cole-Parmer are not intended for and should not be (i) used for medical, surgical or other patient oriented applications, or (ii) combined with any food product or ingested in any form.
This multi-element standard contains 12 elements.
• ICP-MS Interferents Check Solution A3 standard (for SOW-846) is a 125 mL bottle which contains 20,000 µg/mL (20,000 ppm) Chloride; 3,000 µg/mL (3,000 ppm) Calcium; 2,500 µg/mL (2,500 ppm) Iron, Sodium; 2,000 µg/mL (2,000 ppm) Carbon; 1,000 µg/mL (1,000 ppm) Aluminum, Magnesium, Phosphorus, Potassium, Sulfur; and 20 µg/mL (20 ppm) Molybdenum, Titanium.
Hazardous material shipping fees may apply.
Specifications
ConcentrationMultiple
Matrix5% HNO3/tr. HF
Element/IonMultiple
FormLiquid
Volume (mL)125
DOT InformationHazardous; Corrosive liquid, acidic, inorganic, n.o.s, (Nitric acid solution); Class 8, Packing Group III
Storage SymbolAmbient
Hazard SymbolCorrosion
UN NumberUN3264
Shelf Life (months)12
DescriptionICP-MS Interferents Check Solution A3 (for SOW-846) in 5% HNO3/tr. HF; 125 mL